Electrics
The machine is supplied with either a 1.5kW single phase motor or a 1.1kW three phase motor. %nbsp;It is essential that the machine is connected to a suitable supply. We recommend that the machine is installed by a qualified electrician. Always ensure that the electricity supply is cut off at the mains before commencing any repair or maintenance work.
When wired in correctly the machine should run in the direction shown by the arrow on the fan case, i.e. anti-clockwise. The fan should run at 2200/2500 rpm and the plucking plates at 1100/1300 rpm when the motor is running properly.
Dimensions
Height: 1.05 metres. Base of machine: 0.65 metres sq. Weight: 77kg.
Safety Precautions
Care should be taken not to wear loose or baggy clothing that could get caught in the plates when operating the machine, eg scarves, ties, baggy sleeves etc. It is recommended that ear defenders are worn.